Thứ Sáu, 2 tháng 8, 2019

VM600 MPC4 Bo mạch bảo vệ máy Vibro-meter

Card 200-510-SSS

» From the Vibro-Meter® product line
» Continuously online machinery protection card
» Real-time measurement and monitoring using state-of-the-art DSP techniques
» 4 dynamic signal inputs and 2 tachometer (speed) inputs, all individually programmable
» Programmable broad-band and narrow-band filters
» Simultaneous amplitude and phase monitoring in order tracking mode
» Programmable Alert, Danger and OK set points
» Adaptive Alert and Danger levels
» Front panel BNC connectors for easy analysis of raw signals
» 7 front panel LEDs show status and alarms
» Integrated power supply for many Vibro-Meter front-ends, including ICP accelerometers and proximity systems
» Live insertion and removal of cards
» Available in ‘standard’, ‘separate circuits’ and ‘safety’ (SIL) versions
SPECIFICATIONS 200-510-SSS

Dynamic signal inputs
Number of inputs : 4 per MPC4 card
DC range : 0 to +20 V or 0 to −20 V
AC range : ±10 V (maximum)
Common mode voltage range : −50 to +50 V
CMRR : >60 dB at 50 Hz
Crosstalk : −72 dB
Input impedance : 200 kΩ
Current input range
• DC signals : 0 to 25 mA
• AC signals : ±8 mA (maximum)
Analog AC frequency band (without integration): 0.1 Hz to 10 kHz
Analog AC frequency band (with integration): 2.5 Hz to 10 kHz
Analog frequency band for throughput to other cards and buffered AC outputs : DC to 60 kHz (−3 dB)
Current measuring resistor : 324.5 Ω
Processing options
Broad-band
Filtering options : High-pass, low-pass or band-pass
LP/HP ratio in pass band : 500 (maximum)
Ripple : ±0.3 dB
Slope : 6 to 60 dB/octave (software configurable)
Attenuation outside pass band : >50 dB
Amplitude accuracy : ±1% of full-scale
Linearity error : <±1%
Equivalent input noise: <200 µV RMS
Relative shaft vibration
Frequency band
• Vibration : 0.1 Hz to 10 kHz
• Gap/position : DC to 1 Hz
Amplitude accuracy
• Vibration : ±1.2% of full-scale
• Gap/position : ±1% of full-scale
• Linearity error : <±1%
Initial gap/offset compensation : Available
Buffered (raw) dynamic signal outputs
These signals are available on the MPC4 card’s BNC outputs and the IOC4T card’s raw outputs.
Frequency range : DC to 10 kHz (−0.1 dB or 1%).
DC to 60 kHz (−3 dB).
Admissible load on output : >50 kΩ
Amplitude error : <2%
Phase error : <5° (DC to 10 kHz)
Transfer ratio
• Voltage input : 1 V/V
• Current input : 0.3245 V/mA

Ordering number

200-510-SSS-1Hh
200-510-SSS-2Hh
200-510-SSS-3Hh